Amorphous Alloy Dry Type Transformer

Shelf Time: 2024-11-25
Views: 913
Model: Dry Type Transformer
Rated Power: 30KVA~2500KVA
High Voltage: 11KV/23KV/33KV etc.


                                                                              Amorphous Alloy Dry Type Distribution Transformer

1. Scope of application

Amorphous alloy dry type transformer is a new type of low loss, energy saving distribution transformer, which combines the technical advantages of amorphous alloy transformer and traditional epoxy cast dry type transformer, and adopts a new structural form. The transformer with rated capacity ranging from 30KVA to 2500KVA is suitable for AC 50Hz/60Hz, working voltage 6KV-38.5KV and below in the power system, as a substation equipment in the field of power transmission and distribution, infrastructure, public transportation, construction and housing, industry, information technology and new energy.

2. Product standards

    GB/T1094.1    GB/T1094.11      GB/T1094.12       GB/T22072         JB/T10088  

    GB20052        GB/T7354           JB/T3837             GB/T4208          IEC60076-11

3. Operation environment

1) Altitude: ≤1000 meters.

2) Ambient temperature: Maximum +45oC, Minimum -30oC.
3) Relative humidity: ≤90% (+25 oC).

4) Max Ground ramp degree: ≤3°.
5) Seismic level: ≤0.3m/s2 at horizontal direction and ≤0.15m/s2 at vertical direction.
6) Installation environment: No obvious and heavy pollution, no explosive and corrosive gas and dust, with good air ventilation and no severe vibration and shock.
7) If the application environment is different from the above standard conditions, please contact for customized designs.

4. Product advantages

1) Safe flame retardant, fireproof, explosion proof, pollution free, can be directly installed in the load center.

2) Low loss, maintenance free, low comprehensive operating cost, obvious energy saving effect.

3) Good moisture proof performance, can operate normally at 100% humidity, and can be put into operation without pre-drying after decommissioning.

4) Partial discharge capacity< 5Pc, low noise, strong heat dissipation ability.

5) Strong load capacity, low product temperature rise, strong heat dissipation capacity, 140% load when forced air cooling to meet temporary emergency needs

6) Foil coils are insulated with DMD prepreg cloth to improve short circuit resistance and service life.

7) The no-load loss is 70% lower than conventional dry type transformers, and the noise is low.



5.Product Parameters

SCBH5-11-tuya.png


6. Ordering Instructions

When ordering products, please kindly provide below information for confirmation:

Type :                Quantity :       

Rated power:            KVA

Rated voltage :Primary/ Secondary      /      kV

Frequency:60Hz    50Hz

Vector group:Yyn0  Dyn11   Other     

Short-circuit impedance : Standard value    Other      %

No-load/0n-load losses:Standard value    Other      /      KW

Tap range:±5%   ±2x2.5%   Other        

MAX./MIN. ambient temperature: 40/-25    Other     /     

Annual average temperature :20   Other     

Monthly average, of the hottest month:30   Other     

Altitude :口≤1000 m    Other       m

Installation :lndoor    outdoor

Cooling method :AN    AN/AF   

Tap changer :No-load     On-load

Winding material : Copper      Aluminum

Insulation level : Standard value   Other HV:LI/AC     /     kV, LV: LI/AC     /     KV

IP of enclosure:lP00  lP20  Other     

Material of enclosure :Stainless steel  Aluminum alloy

Incoming and outgoing connection :Top/Top  Bottom/Bottom Side/Side  Other     

Bus bar : No    Yes

Other requirements :                                                             