Automatic Reclosing Switch

Shelf Time: 2024-11-25
Views: 873
Model: Outdoor vacuum circuit breaker
Rated Voltage: 11KV/23KV/33KV etc.
Rated current: 630A


                                                                                   Automatic Reclosing Switch

1.Scope of application

Outdoor high voltage vacuum circuit breaker (Automatic Reclosing Switch)  is an outdoor distribution equipment with rated voltage of 12kV and three-phase  alternating current of 50Hz.It is mainly used to open and close load current, overload current and short circuit current in power system.It is suitable for the protection and control in the power distribution system of substation and industrial and mining enterprises, as well as the places where the rural power grid is frequently operated. The circuit breaker has the characteristics of small volume, light weight, anti-condensation, free maintenance and so on. It can adapt to the harsh weather conditions and dirty environment.


2. Product standards

    Comply with GB 1984, IEC  60056 and other standards.


3. Operation environment

1) Altitude: ≤1000 meters.

2) Ambient temperature: Maximum +40ºC, Minimum -40ºC.
3) Max outdoor wind speed: ≤45m/s.

4) Max Ground ramp degree: ≤3°.
5) Seismic level: ≤3m/s2 at horizontal direction and ≤1.5m/s2 at vertical direction.
6) Installation environment: No obvious and heavy pollution, no explosive and corrosive gas and dust, with good air ventilation and no severe vibration and shock.
7) If the application environment is different from the above standard conditions, please contact for customized designs.



4.Product Parameters:

No.ItemUnitData
1Rated voltagekV12
2Rated currentA630
31min power frequency withstand voltageDry test: phase to phase, ground/fracturekV42/48
Wet test: phase to phase, ground/fracturekV34
4Lightning impulse withstand voltage (peak value) phase to phase, ground/fracturekV75/85
5Rated short circuit breaking currentkV20/25
6Rated short circuit making current (peak value)kA50/63
7Rated peak withstand currentkA50/63
84s short-term withstand currentkA20/25
9Rated operating sequence-O-0.3s-CO-180s-CO
10Rated short circuit current breaking timestimes30
11Mechanical lifetimes10000
12Energy storage motor rated voltageVDC24
13Energy storage motor rated powerW70
14Rated operating voltageVDC24
15Energy storage time at rated voltageS<10
16Partial discharge of the whole machinePc<10




5.Ordering Instructions

When ordering products, please kindly provide below information for confirmation:

1) Model, name and quantity.
2) Rated voltage, rated current and rated short-circuit breaking current.
3) Operation mode of operating mechanism (manual, electric, with remote control), type and rated value of operating power supply.
4) Current transformer accuracy level, ratio, quantity.
5) Name and quantity of spare parts.
6) Indicate special requirements via email or call if needed. 